BRONKHORST HIGH-TECH B.V.
2 MODEL CONFIGURATION
E - 7 N N 0 - N N - N N - . . . . .
Module code (14TE)
20 R/C panel + transmitter supply unit for MFM (Ex-proof)
21 R/C panel + supply for MFM (Ex-proof) + control function for valve with XB-coil
22 R/C panel + supply for MFM (Ex-proof) + control function for valve with XC-coil
Code for external output/input signals:
N N - A A
Module output signal
Code
0 - 5 Vdc
0 - 10 Vdc
0 - 20 mA
4 - 20 mA
Other/Specify
A
B
C
D
Z
2.1 Modules
An Ex-proof module is a combination of an R/C panel, a transmitter supply unit and if needed, an isolating
repeater to drive a XB coil. To comply with the intrinsic safe requirements, the system power supply is located
in a separate 14 TE wide location.
2.2 Intrinsic safe electronic units
2.2.1 Transmitter supply unit for flow sensors
Power supply for intrinsic safe flow sensor, providing galvanic isolation between input, output and power
supply.
The unit is a one channel power supply and signal converter. 4(15) - 20 mA input; 4(15) - 20 mA output.
Power supply for the transmitter supply unit is 18 .. 35 Vdc (24 Vdc nominal)/63 mA.
Manufacturer : R. Stahl Schaltgeräte GmbH
Type : ISPac 9160/**-1*-1*
Type of protection II 3 (1) G Ex nA nC [ia] IIC T4
Certificate no. : DMT 03 ATEX E 010 X
Uo = 27 V
Io = 88 mA
Po = 576 mW
Co 90 nF (IIC) / 705 nF (IIB)
Lo 2.3 mH (IIC) / 14 mH (IIB)
Ci negligible
Li negligible
Mechanical data
Dimensions : 17.6 x 108 x 114 mm
Mounting type : on top hat rail 35
Housing
Power supply
Modules
Ext. setpoint/module input signal
0 - 5 Vdc
0 - 10 Vdc
0 - 20 mA
4 - 20 mA
1 - 5 Vdc
Other/Specify
B
C
D
F