Instruction manual
FlowPlot
Software tool for monitoring FLOW-BUS
parameter values and optimizing
controller settings of digital instruments
Doc. no.: 9.17.030O Date: 24-10-2013
ATTENTION
Please read this instruction manual carefully before installing and operating the instrument.
Not following the guidelines could result in personal injury and/or damage to the equipment.
Head Office: Nijverheidsstraat 1a, NL-7261 AK Ruurlo, The Netherlands, Tel. +31 573 458800, [email protected]
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Instruction manual

Instruction manual FlowPlot Software tool for monitoring FLOW-BUS parameter values and optimizing controller settings of digital instruments Doc. no.:

Page 2 - Symbols

BRONKHORST® At Mode, the way the graph behaves when the plot reaches the ‘end’ of the time axis, can be selected: - Scroll: plot lines will be drawn

Page 3 - Table of contents

BRONKHORST® 2.5 PRINTING Printing a hardcopy of the graphs can be very useful to store the measurements. All graphs will be send to printer or file i

Page 4 - 1.4 SYSTEM REQUIREMENTS

BRONKHORST® 2.6 INSTRUMENT SETTINGS 2.6.1 General description This window allows the user to read and change several settings of digital meters and

Page 5 - 2 OPERATION

BRONKHORST® 0 – Bus/RS232 Digital setpoint via fieldbus or RS232 1 – Analog input Setpoint via analog input 3 – Valve fully closed Valve fully closed

Page 6 - 2.1.3 Realtime measurement

BRONKHORST® Factor Responses >= 2 seconds Responses < 2 seconds Dynamic display factor 1.00E-3 3.00E-3 Static display factor 1.00E-2 2.00E-2 S

Page 7 - 2.2 MAIN WINDOW

BRONKHORST® PID-Td is only used if the volume between the sensor and valve is relatively large (e.g. when the sensor and valve are mounted away from

Page 8 - 2.3 SCRIPT

BRONKHORST® The actual valve open voltage or current may be determined automatically once by pressing the button Learn and store. A setpoint step will

Page 9 - 2.4 OPTIONS

BRONKHORST® Valve output steps is a special feature and will set the instrument into a mode in which from the last two setpoints the valve output valu

Page 10 - 2.4.3 File locations

BRONKHORST® Certain readout units contain a relay, which can be switched in case of an alarm. Two modes can be selected at Output: Continuously, the

Page 11 - 2.5 PRINTING

BRONKHORST® 3 SPREADSHEET DATA While FlowPlot is plotting, in the background a comma separated file can be filled with the samples that are taken. Th

Page 12 - 2.6 INSTRUMENT SETTINGS

BRONKHORST® Disclaimer The information in this manual has been reviewed and is believed to be wholly reliable. No responsibility, however, is assumed

Page 13 - 2.6.5 Basic settings

BRONKHORST® 4 SERVICE For current information on Bronkhorst and service addresses please visit our website:  http://www.bronkhorst.com Do you have

Page 14 - 2.6.6 Controller settings

BRONKHORST® Table of contents 1 GENERAL PRODUCT INFORMATION ...

Page 15 - (response setting – 128)

BRONKHORST® 1 GENERAL PRODUCT INFORMATION 1.1 INTRODUCTION This manual will explain the operation of the software tool FlowPlot. It has been written

Page 16

BRONKHORST® 2 OPERATION 2.1 SELECT PARAMETERS After startup, FlowPlot will automatically detect if the communication by FlowDDE to the instrument is

Page 17

BRONKHORST® Device Control mode Description Situation Digital meter or controller 0 – Bus/RS232 Setpoint via bus or RS232 At normal communication wit

Page 18

BRONKHORST® In realtime mode FlowPlot will ask FlowDDE for actual values at the same interval as the realtime poll time, unless the sample time is man

Page 19 - 3 SPREADSHEET DATA

BRONKHORST® The setpoint is the desired value for an instrument or readout unit. 100% will normally be the nominal calibrated value. The buttons at

Page 20 - +31 573 45 88 39

BRONKHORST® In the channel box, the value ‘0’ can be set to let FlowPlot use the setpoint channel. The current setpoint channel is presented at the

Commentaires sur ces manuels

Pas de commentaire