Bronkhorst FLOW-BUS interface Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
BRONKHORST®
2 FIELDBUSINSTALLATION
2.1 GENERAL
FLOW‐BUSis a 3‐wire,RS485‐basedfield buscommunicationsystemfor parameter valueexchangebetweendigital
Bronkhorstproducts.Inthissystemeachinstrument/deviceisequippedwithamicro‐controllerforitsowndedicated
task but also for exchanging parameter value information with other instruments /devices connected to the sam
e
FLOW‐BUSsystem.
FLOW‐BUSsystemsmayhaveaminimumof2andamaximumof126connections.Themaximumlengthfordatelines
between the first and the last connection may be up to approx. 600 meters. Longer distances are only possible in
combination with special bus‐repeater m
odules. Each instrument/device connection T‐part (stub) must be kept as
shortaspossible(maximumcablelength0.5meter).
Thebaudrateusedtotransportmessagesis187500baudor400000*baud.
FLOW‐BUSisamulti‐masternetworkwithatoken‐ringarchitecture.
*MBC3typeinstrumentshaveanadditionalbaudrateavailableof400000baud.
Page11
FLOW‐BUSinterface9.17.024
Vue de la page 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 25 26

Commentaires sur ces manuels

Pas de commentaire