BRONKHORST®
Page29RS232interface 9.17.027
(FlowDDE)Parameternumbers:
Allparameterinformationisreferencedtotheparameternumber.Thisisauniquenumberforaparametertoavoid
redundancy.ThesenumbersareneededforDDEcommunicationonly.
For communication with FLOWBUS throughother ways than DDE: directly via RS232 ASCIIstrings or via Clibraries
(DOS or Windows), use the parameter numbers for the FLOWBUS modules (in column FBnr of table Parameter
properties). Now you will always have to know the nodeaddress of the instrument on the FLOWBUS, the process
numberontheinstrumentandtheparameternumberontheinstrument.
Process
nr could be read from the table or has to be determined, when nothing is filled in. In most cases process
numberwillbe1.Nodeaddressshouldbedeterminedalso.ThisisthenodeaddressoftheinstrumentontheFLOW
BUS. Newer RS232 protocols on Multibus instruments accept
node = 128. When sending messages to this node
address,themessagewillbealwaysaccepted,unregardingthenodeaddressoftheinstrumentonthebus.
ItisimportanttoknowthatnotallparametersareavailableonallFLOWBUS/Multibusdevices.
Formoredetailsaboutparametersandtheiruseseealsodocumentnr.9.17.023fordescriptionof
digitalinstruments.IfyouhavetheprogramFlowDDE,youcanalsogetanoverviewofwhich
parametersareavailableonwhichdevices.
APPENDIX1AND2WILLGIVEINFORMATIONABOUTPARAMETERS,THEIRPROPERTIESANDTHEIRPOSSIBLE
VALUES.